Andersen has been providing the life science industries with Ethylene Oxide
sterilisation solutions since 1958. Today, we have more than 6,000 active users
worldwide![@br@][@br@]Andersen’s continual research and product development
ensures that our state-of-the-art systems are reliable and highly productive.
Operating at a low temperature, sterilisers deliver Ethylene Oxide (EOGas™) to
the load. This gently sterilises the most delicate of devices and eliminate the
risks associated with other methods of sterilisation.
Learn more about the Andersen steriliser range:
Sterilisation cycle time from as low as three and a half hours. The EOGas
Series 4 is ultra-safe for steriliser operators and boasts emission levels well
below prescribed standards.
Andersen’s state-of-the-art gas diffusion technology delivers Ethylene Oxide
directly to the sterilisation load, which means that unlike other sterilisation
systems, you never use more gas than needed. Microorganisms (viruses, bacteria,
fungi and even stubborn bacterial spores) are removed from instruments and
equipment - enabling you to reach the International Standards Organisation's
required sterility assurance level.[@br@][@br@]What is Multi-Load
Processing?[@br@]The Series 3 multi-load steriliser range allows operators to
add and remove bags from the steriliser at any time throughout the
sterilisation process; this is as gas is purged in the chamber. The result: a
versatile and unique system that saves time, labour and
money.[@br@][@br@]Caring for the Environment[@br@]Andersen Products cares about
the environment and its wellbeing. As such, our range of Series 3 Sterilisers
do not use ozone damaging compounds (CFCs, HCFCs, and HFCs) and they are
Environmental Protection Agency (EPA) registered. For further environmental
protection we proudly offer the EOGas Disposer. This dry-bed filter removes up
to 99% of EtO emissions. Our sterilisers also exceed OSHA’s expectations for
personnel safety.
Advantages of the Series 3 EOGas Steriliser range include:[@br@]• International
Standards Organisation (ISO) certified[@br@]• Sterilisation and aeration in the
same cabinet[@br@]• Features a digital display with load tracking
capability[@br@]• Power outage back-up protection
As the saying goes: 'time is money'. The new EOGas Series 4 Steriliser (AN88)
from Andersen unites cutting-edge technology and practicality to bring you our
fastest steriliser to date. Instruments are processed rapidly, eliminating
microorganisms (including resilient bacterial spores), saving you money and
labour. Suitable for literally everything but food, liquid and
drugs.[@br@][@br@]Easy to Install and Operate[@br@]Operating between 40°C-55°C
the Series 4 Steriliser utilises the latest in aeration technology: an advanced
purging device allows sterilisation and aeration to occur in the same chamber
for ease of use. Installation couldn’t be easier. Supplied with a wall mount
installation kit, the AN88 requires only a 7/8” reinforced PVC exhaust line to
the outside. No water or vacuum line is required.[@br@][@br@]Caring for the
Environment[@br@]The EOGas Series 4 Steriliser uses 30-80% less gas than the
nearest competitive systems and complies with OSHA’s requirement for operator
exposure to Ethylene Oxide. No ozone depleting substances are used (CFCs, HFCs
and HCFCs) and for additional environmental protection we offer the AN5100 Gas
Disposer to eliminate 99% of the steriliser’s emissions.
Advantages of the EOGas Series 4 include:[@br@]• International Standards
Organisation (ISO) certified[@br@]• Digital display with load tracking
capability[@br@]• Fully compliant with electrical safety standards[@br@]• Uses
less than 18cc of EtO per cycle
Andersen’s high-tech table-top Anprolene® sterilisers are ideal for small
office-based and medium sterilisation requirements. Ethylene Oxide (EtO) is
delivered to the sterilisation load - killing microorganisms such as viruses,
bacteria, fungi and even resistant bacterial spores, making the International
Standards Organisation’s required sterility assurance level achievable.
Anprolene Sterilisers have the ability to sterilise and preserve a wide variety
of instruments and devices that are sensitive to other sterilisation methods
such as heat, chemical and moisture.[@br@][@br@]Simple to Install and
Operate[@br@]Using 80% less EtO than our nearest competitor, Anprolene
Sterilisers function at room temperature and do not require vacuum lines or
water sources. As sterilisation and aeration occur in the same cabinet, once
the sterilisation cycle has completed items will aerate for a two-hour period
and will continue to do so until the items are removed from the
cabinet.[@br@][@br@]Caring for the Environment[@br@]The protection and
well-being of the environment is important to Andersen. As such, Anprolene
Sterilisers are Environmental Protection Agency registered, and do not use
ozone-depleting substances (CFCs, HCFCs and HFCs). A combination of ventilation
and purge systems in all of the steriliser cabinets ensure that Ethylene Oxide
(EtO) exposure levels are kept below OSHA prescribed
limits.[@br@][@br@]Andersen also offers a dry-bed filter (the Anprolene® Gas
Disposer) to eliminate more than 99% of EtO emissions.
Advantages of the Anprolene Steriliser range include:[@br@]• International
Standards Organisation (ISO) certified[@br@]• For load flexibility there are
three gas dose and bag combination[@br@]• EtO emissions are below those
stipulated by OSHA[@br@]• Designed for small work areas